Parameter |
Resolution |
Accuracy |
Range |
Temperature Measurement & Pressure Measurement |
Flue Temperature Inlet Temperature |
0.1°C
0.1°C |
±1°C ±0.3% reading
±1°C ±0.3% reading |
-50 - 1200°C with suitable probe 0 - 50°C |
Pressure |
0.1mbar |
±0.5% full scale |
150 mbar |
Gas Measurement*1 |
Oxygen |
0.1% |
±0.3% |
0 - 25% |
Carbon Monoxide H2 compensated |
1ppm |
±5ppm <100ppm
±20ppm <400ppm
±5% >400ppm - 2000ppm
±10% >2000ppm - 10000ppm |
0 - 10000ppm
10000 - 20000ppm for 15 mins |
Carbon Monoxide High Range (optional) |
0.01% |
±5% of reading from 0.1% to 10% |
0 - 10% |
Hydrogen Sulphide (optional) |
1ppm |
±5ppm <100ppm
±5% >100ppm |
0 - 200ppm |
Nitric Oxide (optional) |
1ppm |
±5ppm <100ppm
±5% >100ppm |
0 - 5000ppm |
Nitrogen Dioxide (optional) |
1ppm |
±5ppm <100ppm
±10ppm <500ppm
±5ppm >500ppm |
0 - 1000ppm |
Sulphur Dioxide (optional) |
1ppm |
±5ppm <100ppm
±5% >100ppm |
0 - 5000ppm |
Carbon Dioxide Infra-red (optional) |
0.1% |
±0.3% reading |
0 - 20% |
Carbon Dioxide*2 |
0.1% |
±0.3% reading |
0 - 99.9% |
Losses*2 |
0.1% |
±1.0% reading |
0 - 99.9% |
Efficiency*2 |
0.1% |
±1.0% reading |
0 - 120% |
Excess Air*2 |
0.1% |
±0.2% |
0 - 2885.0% |
Temp (Nett)*2 |
1.0°C/F |
±2°C ±0.3% reading |
0 - 1200°C/32 - 2200°F |
CO/CO2 ratio*2 |
0.0001 |
±0.0001 |
0 - 0.9999 |
Poison Index*2 |
0.01% |
±0.01 |
0 - 99.99 |
Pre-programmed Fuels |
Natural Gas (x2), Town Gas, Gascor, Light Oil, Heavy Oil, Propane, Butane, Anthracite, Coke, Coal, Kinsale Gas, User Fuel (x5) |
Dimensions Weight Handset Probe |
1.2kg
240mm x 165 x 65
Dia 8mm with 285mm long stainless steel shaft, type K thermocouple & 3m long neoprene hose |
Ambient Operating Range |
-5°C to +50°C/10% to 90% RH non condensing |
Power Supply (battery charger) |
Input: 110Vac/220 Vac nominal Output: 12 Vac off load |
Battery Life |
>6 hours from full charge |